{"id":77,"date":"2024-09-22T03:09:01","date_gmt":"2024-09-22T03:09:01","guid":{"rendered":"https:\/\/oel.co.th\/product\/?page_id=77"},"modified":"2026-03-14T06:03:33","modified_gmt":"2026-03-14T06:03:33","slug":"explosion-panel-vent-pro","status":"publish","type":"page","link":"https:\/\/oel.co.th\/product\/explosion-panel-vent-pro\/","title":{"rendered":"ATEX Explosion Vent Panel for Dust Collector &#8211; Vent Pro"},"content":{"rendered":"\n<p>Designed to open immediately at a predetermined pressure. Their purpose is to protect the system on which they are installed from an excessive increase in pressure caused by dust or gases.<\/p>\n\n\n\n<p>The explosion venting devices are pressure sensitive and are one of the most basic types of explosion protection. When the static opening pressure is exceeded, the explosion venting device opens and the resulting explosion and pressure are released into the surrounding area in a&nbsp;controlled way without serious damage to the structure of the protected technology. VENT PRO is an effective and economical solution providing protection against damage caused by combustible dust explosions<\/p>\n\n\n\n<p><\/p>\n\n\n\n<div class=\"wp-block-group\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\">\n<div class=\"wp-block-group is-nowrap is-layout-flex wp-container-core-group-is-layout-ad2f72ca wp-block-group-is-layout-flex\">\n<figure class=\"wp-block-image size-large is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"648\" src=\"https:\/\/oel.co.th\/product\/wp-content\/uploads\/2024\/09\/Picture1-4-1024x648.jpg\" alt=\"\" class=\"wp-image-121\" style=\"width:529px;height:auto\" srcset=\"https:\/\/oel.co.th\/product\/wp-content\/uploads\/2024\/09\/Picture1-4-1024x648.jpg 1024w, https:\/\/oel.co.th\/product\/wp-content\/uploads\/2024\/09\/Picture1-4-300x190.jpg 300w, https:\/\/oel.co.th\/product\/wp-content\/uploads\/2024\/09\/Picture1-4-768x486.jpg 768w, https:\/\/oel.co.th\/product\/wp-content\/uploads\/2024\/09\/Picture1-4.jpg 1176w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"365\" height=\"135\" src=\"https:\/\/oel.co.th\/product\/wp-content\/uploads\/2024\/09\/Picture2-2.jpg\" alt=\"\" class=\"wp-image-122\" srcset=\"https:\/\/oel.co.th\/product\/wp-content\/uploads\/2024\/09\/Picture2-2.jpg 365w, https:\/\/oel.co.th\/product\/wp-content\/uploads\/2024\/09\/Picture2-2-300x111.jpg 300w\" sizes=\"auto, (max-width: 365px) 100vw, 365px\" \/><\/figure>\n<\/div>\n\n\n\n<p><\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><mark style=\"background-color:rgba(0, 0, 0, 0)\" class=\"has-inline-color has-nv-c-2-color\">Benefits and Application<\/mark><\/h2>\n<\/div><\/div>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-9d6595d7 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:100%\">\n<pre class=\"wp-block-preformatted\">+ <strong>Dust class St1 \/ St2 \/ St3, hybrid mixtures, metallic \/ non metallic dust<\/strong><br>+ <strong>Static opening pressure variability<\/strong><br>+ <strong>Operating temperature up to 240 C<\/strong><br>+<strong> variability of static activation pressure, including low tolerance (+\/- 15%)<\/strong><br>+ <strong>100% efficiency even for high KSt<\/strong><br>+ <strong>Abrasion resistance, weathering resistance<\/strong><br>+ <strong>Easy installation, minimal maintenance<\/strong><br>+ <strong>Accessories: opening indicators, thermal insulation, installation frames, flame deflector (DivEx)<\/strong><\/pre>\n<\/div>\n<\/div>\n\n\n\n<h2 class=\"wp-block-heading\"><mark style=\"background-color:rgba(0, 0, 0, 0)\" class=\"has-inline-color has-nv-c-2-color\">Venting Devices Types<\/mark><\/h2>\n\n\n\n<div class=\"wp-block-group\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\">\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-9d6595d7 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:100%\">\n<div class=\"wp-block-group is-content-justification-right is-nowrap is-layout-flex wp-container-core-group-is-layout-fd526d70 wp-block-group-is-layout-flex\">\n<figure class=\"wp-block-image size-full is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"642\" height=\"427\" src=\"https:\/\/oel.co.th\/product\/wp-content\/uploads\/2025\/10\/Vent-Pro-F-2.jpg\" alt=\"\" class=\"wp-image-362\" style=\"width:358px;height:auto\" srcset=\"https:\/\/oel.co.th\/product\/wp-content\/uploads\/2025\/10\/Vent-Pro-F-2.jpg 642w, https:\/\/oel.co.th\/product\/wp-content\/uploads\/2025\/10\/Vent-Pro-F-2-300x200.jpg 300w\" sizes=\"auto, (max-width: 642px) 100vw, 642px\" \/><figcaption class=\"wp-element-caption\"><strong><mark style=\"background-color:rgba(0, 0, 0, 0)\" class=\"has-inline-color has-neve-link-hover-color-color\">Vent Pro F &#8211; Flat Rectangular<\/mark><\/strong><br>suitable for applications with low operational pressure; for equipment with an operating temperature up to 100 \u00b0C; <strong>installation without top flange<\/strong>; stainless steel; <strong>curved: radius on request<\/strong>; certification according to EN&nbsp;14797, 2014\/34\/EU <\/figcaption><\/figure>\n\n\n\n<p><\/p>\n\n\n\n<figure class=\"wp-block-image size-full is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"642\" height=\"427\" src=\"https:\/\/oel.co.th\/product\/wp-content\/uploads\/2025\/10\/Vent-Pro-S.jpg\" alt=\"\" class=\"wp-image-363\" style=\"width:380px;height:auto\" srcset=\"https:\/\/oel.co.th\/product\/wp-content\/uploads\/2025\/10\/Vent-Pro-S.jpg 642w, https:\/\/oel.co.th\/product\/wp-content\/uploads\/2025\/10\/Vent-Pro-S-300x200.jpg 300w\" sizes=\"auto, (max-width: 642px) 100vw, 642px\" \/><figcaption class=\"wp-element-caption\"><strong><mark style=\"background-color:rgba(0, 0, 0, 0)\" class=\"has-inline-color has-neve-link-hover-color-color\">Vent Pro S &#8211; Domed Rectangular<\/mark><\/strong><br>domed single-layer construction; for devices with operating temperatures up to 230 \u00b0C; integrated installation frame; suitable for devices with pressure shocks; suitable for food, pharmacy and chemical industry; stainless steel; certification according to EN&nbsp;14797, 2014\/34\/EU<\/figcaption><\/figure>\n<\/div>\n<\/div>\n<\/div>\n<\/div><\/div>\n\n\n\n<h2 class=\"wp-block-heading\"><mark style=\"background-color:rgba(0, 0, 0, 0)\" class=\"has-inline-color has-nv-c-2-color\">Suitable For<\/mark><\/h2>\n\n\n\n<div class=\"wp-block-columns are-vertically-aligned-center is-layout-flex wp-container-core-columns-is-layout-9d6595d7 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-vertically-aligned-center is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:100%\">\n<pre class=\"wp-block-code\"><code><strong>&gt; Filtration Units\n&gt; Silos\n&gt; Bins\n&gt; Mills\n&gt; Crushers\n&gt; Dust Separators\n&gt; Cyclones\n&gt; And other industrial equipments<\/strong><\/code><\/pre>\n<\/div>\n<\/div>\n\n\n\n<h5 class=\"wp-block-heading\">Request Explosion Vent Sizing Contact OEL Engineer for Vent Area Calculation<\/h5>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<p><strong>Contact : 099-017-7779<br>Email : oel_engineer@outlook.com<br>Line ID : santithep_s<\/strong><\/p>\n\n\n\n<figure class=\"wp-block-image size-full is-resized\"><a href=\"http:\/\/line.me\/ti\/p\/~santithep_s\"><img loading=\"lazy\" decoding=\"async\" width=\"147\" height=\"41\" src=\"https:\/\/oel.co.th\/product\/wp-content\/uploads\/2024\/09\/line.gif\" alt=\"\" class=\"wp-image-73\" style=\"width:204px;height:auto\"\/><\/a><\/figure>\n\n\n\n<p><\/p>\n\n\n\n<p><\/p>\n\n\n\n<p><\/p>\n\n\n\n<p><\/p>\n","protected":false},"excerpt":{"rendered":"<p>Designed to open immediately at a predetermined pressure. Their purpose is to protect the system on which they are installed from an excessive increase in pressure caused by dust or gases. The explosion venting devices are pressure sensitive and are one of the most basic types of explosion protection. When the static opening pressure is&hellip;&nbsp;<a href=\"https:\/\/oel.co.th\/product\/explosion-panel-vent-pro\/\" class=\"\" rel=\"bookmark\">Read More &raquo;<span class=\"screen-reader-text\">ATEX Explosion Vent Panel for Dust Collector &#8211; Vent Pro<\/span><\/a><\/p>\n","protected":false},"author":2,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"neve_meta_sidebar":"","neve_meta_container":"","neve_meta_enable_content_width":"","neve_meta_content_width":0,"neve_meta_title_alignment":"","neve_meta_author_avatar":"","neve_post_elements_order":"","neve_meta_disable_header":"","neve_meta_disable_footer":"","neve_meta_disable_title":"","footnotes":""},"class_list":["post-77","page","type-page","status-publish","hentry"],"_links":{"self":[{"href":"https:\/\/oel.co.th\/product\/wp-json\/wp\/v2\/pages\/77","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/oel.co.th\/product\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/oel.co.th\/product\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/oel.co.th\/product\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/oel.co.th\/product\/wp-json\/wp\/v2\/comments?post=77"}],"version-history":[{"count":17,"href":"https:\/\/oel.co.th\/product\/wp-json\/wp\/v2\/pages\/77\/revisions"}],"predecessor-version":[{"id":380,"href":"https:\/\/oel.co.th\/product\/wp-json\/wp\/v2\/pages\/77\/revisions\/380"}],"wp:attachment":[{"href":"https:\/\/oel.co.th\/product\/wp-json\/wp\/v2\/media?parent=77"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}